Mitsubishi Programmable Logic ControllerAnalog-Digital Converter Module type AJ65SBT-64ADUser,s Manual
A - 9Product componentsThis product consists of the following.Product Name QuantityType AJ65SBT-64AD analog-digital converter module1Type AJ65SBT-64AD
A - 10MEMO
1 - 1MELSEC-A1 OVERVIEW 11 OVERVIEWThis user's manual explains the specifications, handling, programming methods andothers of Type AJ65SBT-64A
1 - 2MELSEC-A1 OVERVIEWMEMO
2 - 1MELSEC-A2 SYSTEM CONFIGURATION 22 SYSTEM CONFIGURATIONThis chapter describes the system configuration for use of the AJ65SBT-64AD.2.1 Overall
2 - 2MELSEC-A2 SYSTEM CONFIGURATION2.2 Applicable SystemThis section explains the applicable system.(1) Applicable master modulesThe following mas
3 - 1MELSEC-A3 SPECIFICATION 33 SPECIFICATIONThis chapter provides the specifications of the AJ65SBT-64AD.3.1 General SpecificationTable 3.1 indica
3 - 2MELSEC-A3 SPECIFICATION3.2 Performance SpecificationTable 3.2 indicates the performance specifications of the AJ65SBT-64AD.Table 3.2 Performanc
3 - 3MELSEC-A3 SPECIFICATION3.3 I/O Conversion CharacteristicsThe I/O characteristics is the slope created by connecting the offset and gain values,
3 - 4MELSEC-A3 SPECIFICATION3.3.1 Voltage input characteristicsThe voltage input characteristic graph is shown below.321409540002000-2000-4000-40960
A - 1 SAFETY PRECAUTIONS (Always read these precautions before using this equipment.)Before using this product, please read this manual and the releva
3 - 5MELSEC-A3 SPECIFICATION3.3.2 Current input characteristicsThe current input characteristic graph is shown below.21409540002000-2000-400004-30 -
3 - 6MELSEC-A3 SPECIFICATION3.3.3 Relationship between the offset/gain setting and digital output valueThe relationship between the offset/gain sett
3 - 7MELSEC-A3 SPECIFICATION4000020mA0Varies within the range of±0.2% (±8 digit) at operatingambient temperature of 25±5 .Varies within the range
3 - 8MELSEC-A3 SPECIFICATION3.4 Function ListThe AJ65SBT-64AD function list is shown in table 3.3.Table 3.3 AJ65SBT-64AD function listItem Descripti
3 - 9MELSEC-A3 SPECIFICATION3.4.1 Sampling processingThe A/D conversion is performed successively for the analog input, and the converteddigital out
3 - 10MELSEC-A3 SPECIFICATION3.5 Remote I/O SignalsThis section describes the assignment and functions of the remote I/O signals.3.5.1 Remote I/O si
3 - 11MELSEC-A3 SPECIFICATION3.5.2 Functions of the remote I/O signalsTable 3.5 explains the functions of the remote I/O signals of the AJ65SBT-64AD
3 - 12MELSEC-A3 SPECIFICATIONTable 3.5 Remote I/O Signal Details (2/2)Device No. Signal Name DescriptionRX(n+1)A Error status flagTurns on when CH.
3 - 13MELSEC-A3 SPECIFICATION3.6 Remote RegisterThe AJ65SBT-64AD has a remote resister for data communication with the mastermodule. The remote regi
3 - 14MELSEC-A3 SPECIFICATION3.6.2 A/D conversion enable/prohibit specification (Address RWwm)(1) Set whether A/D conversion is enabled or disable
A - 2[Installation Precautions]! CAUTION Use the PLC in the environment that meets the general specifications contained in this Manual.Using the PLC o
3 - 15MELSEC-A3 SPECIFICATION3.6.3 Input range setting (Address RWwm+1)(1) Set the analog input range per channel.(2) Operation is performed acc
3 - 16MELSEC-A3 SPECIFICATION3.6.4 Moving average processing count setting (Address RWwm+2)(1) Set the average processing count of the channel for
4 - 1MELSEC-A4 SETUP AND PREPARATION BEFORE OPERATION 44 SETUP AND PREPARATION BEFORE OPERATION4.1 Pre-Operation ProcedureThis section explains the
4 - 2MELSEC-A4 SETUP AND PREPARATION BEFORE OPERATIONCAUTION Dispose of the product as industrial waste. Use the module in the environment indicated
4 - 3MELSEC-A4 SETUP AND PREPARATION BEFORE OPERATION4.3 Name of Each PartThe name of each part in the AJ65SBT-64AD is shown.PW RUN L RUN L ERR. CH1
4 - 4MELSEC-A4 SETUP AND PREPARATION BEFORE OPERATIONNumberName andappearanceDescriptionUse the switches in STATION NO. "10", "20&quo
4 - 5MELSEC-A4 SETUP AND PREPARATION BEFORE OPERATION4.4 Offset/Gain SettingWhen changing the I/O conversion characteristics, follow the procedure b
4 - 6MELSEC-A4 SETUP AND PREPARATION BEFORE OPERATIONPOINT(1) Set the offset and gain values in the actual usage state.(2) The offset and gain value
4 - 7MELSEC-A4 SETUP AND PREPARATION BEFORE OPERATION4.5 Station Number SettingThe station number setting of the AJ65SBT-64AD determines the buffer
4 - 8MELSEC-A4 SETUP AND PREPARATION BEFORE OPERATION4.7 Data Link Cable WiringThis section explains the wiring of the CC-Link dedicated cable used
A - 3[Wiring Precautions]! CAUTION When connecting the communication and power supply cables to the module, always run themin conduits or clamp them.N
4 - 9MELSEC-A4 SETUP AND PREPARATION BEFORE OPERATION4.8.2 Module connection exampleV+I+COMSLDV+I+COMSLDFG1CH1+15V-15VGND*4*1 Shield*5*3CH4*2AGFor v
4 - 10MELSEC-A4 SETUP AND PREPARATION BEFORE OPERATIONMEMO
5 - 1MELSEC-A5 PROGRAMMING 55 PROGRAMMINGThe programming procedure, basic read/write programs, and program examples forthe AJ65SBT-64AD are describ
5 - 2MELSEC-A5 PROGRAMMING5.2 Program ExamplesThis section provides the program examples of the AJ65SBT-64AD.5.2.1 Program examples for use of the A
5 - 3MELSEC-A5 PROGRAMMING(1) Program example for power-onInitial settings of master stationRead of remote input signalsChecking of AJ65SBT-64ADst
5 - 4MELSEC-A5 PROGRAMMINGProcessing at error occurrenceMasks disabled devices.Write of remote output signalsUser designationReads error.Turns on er
5 - 5MELSEC-A5 PROGRAMMING(2) Program example for initial data changingInitial settings of master stationRead of remote input signalsCheckingofAJ6
5 - 6MELSEC-A5 PROGRAMMINGProcessing at error occurrenceMasks disabled devices.Write of remote output signalsUser designationReads error.Turns on er
5 - 7MELSEC-A5 PROGRAMMING5.2.2 Program examples for use of the ACPU/QCPU (A mode) (dedicated instructions)The program examples in this section are
5 - 8MELSEC-A5 PROGRAMMING(1) Program example for power-onSetting of network parametersSetting of automatic refresh parametersSynchronization mode
A - 4REVISIONS* The manual number is given on the bottom left of the back cover.Print Date * Manual Number RevisionOct., 2000 SH (NA) 080106-A First p
5 - 9MELSEC-A5 PROGRAMMINGSetting of automatic refresh parametersChecking of AJ65SBT-64AD statusInitial settingsRead of digital valuesProcessing at
5 - 10MELSEC-A5 PROGRAMMING(2) Program example for initial data changingSetting of network parametersSetting of automatic refresh parametersSynchr
5 - 11MELSEC-A5 PROGRAMMINGSetting of automatic refresh parametersChecking of AJ65SBT-64AD statusInitial settingsRead of digital valuesProcessing at
5 - 12MELSEC-A5 PROGRAMMING5.2.3 Program examples for use of the QnACPUThe program examples in this section are created under the following conditio
5 - 13MELSEC-A5 PROGRAMMING[Automatic refresh parameter setting](1) Program example for power-onChecking of AJ65SBT-64AD statusInitial settingsRea
5 - 14MELSEC-A5 PROGRAMMING(2) Program example for initial data changingChecking of AJ65SBT-64AD statusInitial settingsRead of digital valuesProce
5 - 15MELSEC-A5 PROGRAMMING5.2.4 Program examples for use of the QCPU (Q mode)The program examples in this section are created under the following c
5 - 16MELSEC-A5 PROGRAMMING[Automatic refresh parameter setting](1) Program for power-onAt power-on, the initial setting of the AJ65SBT-64AD can b
5 - 17MELSEC-A5 PROGRAMMING(c) Setting resultsThe setting results of 1) to 8) are shown below.(d) Program exampleChecking of AJ65SBT-64AD status
5 - 18MELSEC-A5 PROGRAMMING(2) Program for initial data changingWhen any initial data (conversion processing system, input range, A/Dconversion en
A - 5INTRODUCTIONThank you for choosing a Mitsubishi MELSEC-A Series General Purpose Programmable Controller.Before using your new PLC, please read th
6 - 1MELSEC-A6 TROUBLESHOOTING 66 TROUBLESHOOTINGThe details of the errors which may occur when using the AJ65SBT-64AD andtroubleshooting are descr
6 - 2MELSEC-A6 TROUBLESHOOTING6.2 Using the LED Indications to Check ErrorsThis section explains how to check errors using the LED indications of th
6 - 3MELSEC-A6 TROUBLESHOOTING(5) When the AJ65SBT-64AD "L ERR." LED flickers at fixed intervalsCheck item Corrective actionHas the stat
6 - 4MELSEC-A6 TROUBLESHOOTING6.3 When the digital output value cannot be readCheck item Corrective actionIs the "PW" LED off? Take action
6 - 5MELSEC-A6 TROUBLESHOOTING6.4 Troubleshooting for the Case where the "ERR." LED of the Master Station FlickersThe "ERR"LED o
6 - 6MELSEC-A6 TROUBLESHOOTINGAre thestation numbersetting switches properly(not overlapping withother stations)?Set the station numbersetting switc
Appendix - 1MELSEC-AAPPENDIX APPAPPENDIXAppendix1 Comparison between This Product and Conventional Product(1) Comparison in performance between this
Appendix - 2MELSEC-AAPPENDIX(2) Precautions for replacing the conventional product (AJ65BT-64AD)with the AJ65SBT-64ADIn the existing system using th
Appendix - 3MELSEC-AAPPENDIXAppendix2 External dimension diagramThe outline dimension drawing of the AJ65SBT-64AD is shown below.NP402-4.5 5.1 inst
Appendix - 4MELSEC-AAPPENDIXMEMO
A - 64 SETUP AND PREPARATION BEFORE OPERATION 4- 1 to 4- 104.1 Pre-Operation Procedure...
Index - 1INDEX[A]A/D conversion completion flag ... 3-11A/D conversion enable/prohibit specification...
Index - 2[S]Sampling processing... 3-9SELECT/SET switch ... 4-3Station number
Index - 3MEMO
WARRANTYPlease confirm the following product warranty details before starting use.1. Gratis Warranty Term and Gratis Warranty RangeIf any faults or de
When exported from Japan, this manual does not require application to theMinistry of International Trade and Industry for service transaction permissi
A - 7About ManualsThe following manuals are also related to this product.In necessary, order them by quoting the details in the tables below.Related M
A - 8About the Generic Terms and AbbreviationsUnless otherwise specified, the following generic terms and abbreviations are used inthis manual to desc
Comments to this Manuals